Developing data

Dilution, EI, temperature and time for each film × developer

Share a dev record
5 combinations
FilmDeveloperDilutionEIPush/pullTempTimeAgitationSource
Ilford HP5 PlusIlford ID-11stock400±020℃ / 68℉7:30Continuous for the first 10 s, then 10 s every minute (4 inversions)Ilford HP5 Plus datasheet
Sample data. Always check the manufacturer datasheet before developing.
Ilford HP5 PlusIlford ID-111+1400±020℃ / 68℉13:00Continuous for the first 10 s, then 10 s every minute (4 inversions)Ilford HP5 Plus datasheet
Sample data. Always check the manufacturer datasheet before developing.
Kodak Tri-X 400Kodak D-76stock400±020℃ / 68℉6:45Continuous for the first 30 s, then 5 s every 30 sKodak Tri-X datasheet (F-4017)
Sample data. Always check the manufacturer datasheet before developing.
Kodak Tri-X 400Kodak D-761+1400±020℃ / 68℉9:45Continuous for the first 30 s, then 5 s every 30 sKodak Tri-X datasheet (F-4017)
Sample data. Always check the manufacturer datasheet before developing.
Kodak Tri-X 400Kodak HC-110Dilution B (1+31)400±020℃ / 68℉3:45Continuous for the first 30 s, then 5 s every 30 sKodak Tri-X datasheet (F-4017)
Sample data. Always check the manufacturer datasheet before developing.

Times and temperatures are a starting point. Test a roll before relying on a new combination.